A written report with readings, photos and what we'd do next, emailed to you on the day. Servicing Sydney homes and businesses since 1991.
What You Get With Every Jay's Air Conditioning Service
A Proper Record, Not Just Our Word For It
Most air con services end with a bloke saying "all good mate" and an invoice. Ours end with a report.
Every Standard Service ($250+GST, $110+GST for each extra unit) and Platinum Service ($350+GST) comes with a written report emailed to you the same day. It lists the system's make, model and serial numbers, the readings we took, what we found and what we'd recommend. Photos go in too, so you can see the dirty filter or the crushed duct for yourself.
It's handy for more than peace of mind. You've got a record for warranty claims, a history to hand the next tech, and something to show a landlord, body corporate or property manager.
What's in every report
- Job number, date and who attended
- The system: brand, model, serial numbers, refrigerant type and size
- What we did, step by step, with the readings we took
- What we found, in plain English
- What we recommend, and what can wait
- Photos from the job
Below are three real reports from the last few weeks, written up section by section. Customer names and addresses are left out.
Report 1: "It's Not Cooling Like It Used To"
Daikin 22kW ducted system, Edmondson Park. The customer booked a general service because the system wasn't keeping up. It's a Daikin RZYQ8TY1 on R410A, built in 2022, so it's not old.
The readings looked fine at first
Standing pressure was 1339 kPa at 20 degrees, right where it should be for R410A. The outdoor unit was drawing 10.74, 11.05 and 11.24 amps across the three phases, well under its 16.1 amp maximum. No leak, no electrical issues.
But after 30 minutes in cooling, suction pressure settled at around 635 kPa. That puts the indoor coil at about minus 2.5 degrees, which is too cold for a mild day. That's the tell-tale sign the indoor unit isn't getting enough air across the coil.
The real problem was in the roof
Up in the roof space, the return air duct had collapsed where it runs against the steel ceiling framing. It was choking off the air coming back to the unit. On top of that, the 900 x 500 return grille feeding two 400 mm ducts is undersized for a 22kW system.
What we recommended
Replace the collapsed section of duct and support it so it can't get crushed again. While we're up there, upgrade the return grille and ducting to suit the system. A gas top-up or a new unit wouldn't have fixed this one. If your ducted system is running but not cooling, our ducted air conditioning repairs page covers the usual airflow culprits.
Report 2: Four Complaints, One Visit
Panasonic 12.5kW ducted system. This customer had a list: uneven airflow front to back, a rattle when the system runs on low, water coming in upstairs in high winds, and interest in app control. It's a Panasonic U-125PZ3R5 on R32, made in 2021.
Health check first
Standing pressure 1291 kPa, holding its charge. Compressor drawing 12.03A against a 16.1A rating, indoor fan 1.30A against 2.52A. Suction around 642 kPa with about 5K superheat, so the gas charge is correct. The filter was filthy enough to hurt performance, so it got washed and chemically cleaned.
Then the four complaints
Airflow. The upstairs dampers were half shut, so we opened them up. The kitchen is big, west-facing and cops the afternoon sun, and one outlet can't keep up with that load. A separate split for the kitchen is the honest fix there.
The rattle. The outdoor unit is bolted straight to the slab with no rubber feet, so at certain speeds the vibration carries into the house. Anti-vibration pads sort that.
The water. Disconnected vent tubes in the roof. Not an air con problem at all, and the report says so.
App control. A Panasonic CONEX controller can do it, and the report explains how it works with their two wall controllers.
The recommendations, in order
We also flagged cable joins sitting next to a dripping gas line with no junction box, and bare copper where the insulation had slipped. Small jobs now. Expensive ones if they're left.
Report 3: Six Split Systems At A Vet Clinic
We were called to a vet clinic because the reception unit was vibrating heavily. We serviced all six Daikin split systems on site, across reception, treatment, the lab and recovery area, and the consult rooms.
What we found
Every unit had heavy mould and mildew on the fan barrels and coils. The reception unit's vibration came from mould build-up throwing the fan barrel out of balance. Once it was cleaned it ran smooth and quiet. Where a barrel could come out, we removed and washed it. Where it couldn't, we chemically cleaned and scrubbed it in place.
Why it matters in a clinic
Mould on the coil gets blown into the room every time the unit runs. In a clinic, that means staff and recovering animals breathing it all day. Dirty coils also make the units work harder, so they cost more to run and wear out sooner.
Our recommendation was a clean and service every six months, with a condition check on each system. If you look after a clinic, practice or office, have a look at our commercial air conditioning page or our preventative maintenance plans.
More Real Jobs From Around Macarthur
More real jobs, by area
Every one of these is a real report from the last few months. Each one explains the problem, how we tracked it down and what we did, with the readings and photos. Customer details are left out.
Camden, Mount Annan and Spring Farm
- Servicing Older R22 Systems: Two Daikin Ducted in Mount Annan
- Ducted Running But Not Cooling: A Real Spring Farm Job
Narellan
Oran Park, Gregory Hills and Leppington
- Daikin U4 Error: What It Means, and a Real Oran Park Job
- What a Ducted Service Should Cover: A Real Oran Park Job
- What Superheat Tells Us: A Gregory Hills Early Warning
- How a Proper Refrigerant Leak Test Works: A Leppington Daikin
- Air Con Tripping the Breaker: A Real Actron Fix in Leppington
Campbelltown, Bradbury, Woodbine, Rosemeadow and Airds
- Air Con Service Report for a Commercial Lease: Campbelltown
- Samsung E422 Error: What It Means, and a Real Bradbury Job
- Signs Your Old Ducted System Is Near the End: Woodbine
- Why Some Rooms Get No Air: A Real Rosemeadow Job
- Actron PC01 Fault: What It Means, and a Real Airds Job
Minto, Ingleburn, Edmondson Park and Bardia
- What's in a Split System Strip Clean: A Real Minto Job
- High Head Pressure Explained: A Daikin Service in Ingleburn
- Is It the Capacitor? A Real Ingleburn Diagnostic
- Why a New Ducted System Won't Cool: Edmondson Park
- Corroded Indoor Coil on a Geothermal System: Edmondson Park
- Gas Leak in the Pipework: A Real Mitsubishi Electric Job
- Why a Ducted Zone Stops Working: A Real Bardia Job
Book a service and get your own report
Standard Service is $250+GST for the first unit and $110+GST for each extra one. Platinum is $350+GST. Full details are on our pricing page.
Give us a call on (02) 9820 4500 or book a service online. Our own crew, not subbies. NSW contractor licence 273312C, ARCtick AU13058.
Service reports
Service Report Questions
Yes. Every Standard and Platinum Service comes with a written report with photos, emailed to you on the day. The $150+GST filter service is just a filter clean, so it doesn’t include readings or a report.
The Standard Service ($250+GST) covers filters, electrical checks, refrigerant pressure readings, coil inspection and the drain line, all written up with photos. Platinum ($350+GST) adds a full loaded run cycle of 20 to 35 minutes with live digital readings and full amp draws, written up as a measurement report.
Yes. It lists the model and serial numbers, the date, the readings and who did the work, which is what manufacturers, landlords and property managers usually want to see.
No. If it can be fixed, the report says so. In the first report on this page the fix was ductwork, not a new unit. When something isn’t an air con problem, like the roof vents in the second report, we say that too.
Our own crew, not subbies. Jay’s Air Conditioning has been servicing Sydney homes and businesses since 1991, with NSW contractor licence 273312C and ARCtick AU13058.