Panasonic Ducted Replacement – Samantha Riley Drive, Bella Vista
10-year-old Actron Air ducted system in a project home on Samantha Riley Drive had developed a failed compressor. Repair quote came in close to replacement cost, so the customer chose to replace. Existing duct runs and zone controller wiring were still serviceable.
Installed Panasonic 12kW 5-zone ducted system. Reused all existing ductwork and zone wiring – which saved several thousand on the total cost. New indoor unit, new outdoor unit on the existing concrete pad. Clean one-day job. Supply and install $9,800.