Not a top-up. A nitrogen and tracer gas test, done in sections and logged, on a Daikin 14kW ducted in Leppington.
How a Proper Refrigerant Leak Test Works: A Leppington Daikin
How A Proper Refrigerant Leak Test Works
An air conditioner is a sealed system. If it's low on gas, it has a leak, and topping it up just puts more gas into the same hole. The fix is to find the leak first.
We fill the system with nitrogen mixed with a tracer gas and watch the pressure on a digital gauge that logs every reading. A sealed system holds its pressure. If there's a leak, the pressure slowly drops as the gas escapes. A small rise is normal, because gas expands as the day warms up.
Our leak test, step by step
- Recover any refrigerant left in the system.
- Pressurise with nitrogen and a tracer gas.
- Test the system in sections. If a section holds on its own, the leak isn't there.
- Log every stage on a digital gauge: start pressure, finish pressure and time.
- Sweep everything we can reach with an electronic leak detector that picks up the tracer gas.
- Tighten and check every valve and service port, because these can leak too.
- If the result is unclear, leave it under pressure and come back to recheck.
- Once it's proven sealed, evacuate and recharge. If it isn't, find the section and quote the repair.
What not to do
- Don't just top up the gas. It'll leak straight back out.
- Don't run the system while it's under test. It can't run with nitrogen in it.
- Don't trust a quick look. Small leaks only show up over time, which is why we log the readings.
See regas costs and rules and Daikin repairs.
The Job
- Suburb: Leppington
- Job: Refrigerant leak find (in progress)
- System: Daikin 14kW ducted, R32, built 2020
The customer wanted their refrigerant leak found and fixed properly, not just topped up and sent on its way.
What We Found
We pressure tested the system with nitrogen and a trace gas, in sections, so we could narrow down where a leak might be. Each stage was logged on our digital gauges.
With both sections joined, the pressure dropped around 2 kPa a minute, but that didn't repeat. So no leak is confirmed yet. Pressure moves with temperature, and a slow leak can take time to show.
The readings
- Stage 1: 3,032 to 3,045 kPa over 25 minutes
- Stage 2: 2,641 to 2,625 kPa over 9 minutes
- Stage 3: 2,625 to 2,628 kPa
- Stage 4: 2,628 to 2,638 kPa
What We Did And Recommended
We tightened the valves and service ports and left the system holding nitrogen at 2,638 kPa. We'll be back in one to two weeks to recheck. If it's held, we evacuate and regas. If it's dropped, we find the leak and quote the repair.
This job's still in progress. We'll update this page when it's done.
Why not just top it up? Because the gas goes straight back out. See regas costs and rules, Daikin repairs, and air conditioning in Leppington.
FAQ
Common Questions
We fill the system with nitrogen and a tracer gas, test it in sections, log the pressure over time, and sweep it with an electronic leak detector. A section that holds pressure is ruled out.
Because the gas is going somewhere. Topping up without fixing the leak means paying for refrigerant again and again. R32 is $185/kg and R410a is $225/kg.
Gas expands as it warms up. On a sunny day, the pressure can creep up even when the system is perfectly sealed. That’s why we note the temperature and sun exposure.
A first test takes a few hours on site. If the result is mixed, like this Leppington job, we leave it under pressure and come back in a week or two to recheck.
Get A Report Like This For Your System
Every Standard Service ($250+GST, $110+GST for each extra unit) comes with a written report like this one, with readings and photos, emailed to you the same day. Diagnostics are $250+GST and come with a written report too.
Give us a call on (02) 9820 4500 or book online. Our own crew, not subbies. NSW contractor licence 273312C, ARCtick AU13058. Servicing Sydney since 1991.